Engine Testing
نظرة عامة على الصناعة
الميزات الرئيسية
Gasoline and diesel automobile engines
Truck and other high speed diesel engines
Medium speed diesel engines such as those used for locomotives, marine and power generation
Extremely large low speed diesel engines for marine propulsion and power generation
Motorcycle engines
High performance race car engines
Challenges
Engine testing can be time consuming and expensive due to fuel usage, support requirements and labor. Therefore, oil samples are taken to check for abnormal wear so that testing may be curtailed if abnormal wear is occurring. Not only does this early intervention save time and fuel, but it may prevent secondary damage in an engine headed toward failure.
Reliability testing is a very important component of new engine development. Engineers need to fully understand and chart the engine's performance under a variety of conditions before mass production may be considered. Oil analysis is an integral part of the research, development and testing process.
Comprehensive real time oil analysis can provide critical information about both engine condition and the condition of the lubricant. Due to the limited capabilities of in-line oil sensors that are attached to the test engine, it can be difficult to isolate and identify engine wear data or know the complete condition of the lubricant.
Having the optimum oil analysis instrumentation within close proximity to the test cell will provide that critical data in real time. Choosing the right oil analysis instrument to gather this data is not as obvious as it may sound due to the challenges of the operating environment. During accelerated wear testing, oil analysis reporting may be required at 10 to 15 minutes intervals. This leaves a very limited time for engineers to perform the test and analyze the results once the oil sample has been collected. This puts a premium on sample turnaround time.
الاختبارات والتطبيقات النموذجية
Break-in wear - During the new engine break-in period, larger adhesive (sliding) wear particles are generated at a higher rate than during normal operating conditions. Continuously trending the sliding wear rate helps engineers understand the engine break-in pattern.
Normal wear – Running engines continuously generates small rubbing wear particles from all the moving parts inside. Elemental analysis is the best method to analyze small wear particles and trace them back to the source of wear through elemental identification.
Chemistry
Total Acid Number (TAN) - TAN is measured to determine the corrosive potential of lubrication oils. If the TAN gets too high the oil can induce corrosion of machine parts and should be changed.
Total Base Number (TBN) - TBN measures the amount of active acid neutralizing additive left in a sample of oil. The TBN is useful for people who want to extend their oil usage far beyond the normal range. The TBN of a used oil can aid the user in determining how much reserve additive the oil has left to neutralize acids. The lower the TBN reading, the less active additive the oil has left.
Viscosity - The main function of lubrication oil is to create and maintain a lubrication film between two moving metal surfaces. Ensuring the viscosity is within recommended ranges is one of the most important tests one can run on lube oil.
Oxidation, Nitration, Sulfation - Lubricating oil at elevated temperatures can react with oxygen and nitrogen in the atmosphere, as well as sulfur in fuel, to form undesirable by-products that can affect the oil's viscosity and lead to corrosion or damage of equipment.
Contamination
Fuel Dilution - Fuel dilution in oil is a condition caused by excess, unburned fuel mixing with engine oil in an engine crankcase. Hydrocarbon-based fuel, usually with a lower vapor pressure than the lubricant, has a thinning effect, lowering the oil viscosity. Oil film strength is reduced, increasing the cylinder liner and bearing wear.
Soot - Soot is a product of diesel combustion and has always been found in engine oils. Soot can use up an oil's additives and deposit on vital engine surfaces.
Glycol - Glycol is found in engine coolant. If glycol is found in engine oil it typically indicates there is a leak in the engine that needs to be addressed.
موارد الصناعة
لا تتوفر موارد
نقوم حالياً بتحديث مكتبة الموارد لهذه الصناعة. عد قريباً أو اتصل بنا لطلب وثائق محددة.
طلب الوثائقالمنتجات الداعمة
Oil Analysis
أكوا 40.00 فاريـو
AQUA 40.00 Vario هو محلل رطوبة Karl Fischer متعدد الاستخدامات مصمم ل...
Oil Analysis
أكواماكس KF برو غاز البترول المسال
Aquamax KF PRO LPG هو جهاز معايرة Karl Fischer الكولومتري متخصص ل...
Oil Analysis
أكواماكس KF برو زيت
Aquamax KF PRO Oil هو جهاز معايرة Karl Fischer الكولومتري عالي الأد...
Oil Analysis
سلسلة فيرو تشيك 2000
PA100 هو جهاز فيروغرافي مكتبي متقدم مصمم للتحليل النوعي و...
Oil Analysis
سلسلة فلويد سكان 1000
جهاز FluidScan هو مطياف أشعة تحت الحمراء محمول باليد يُستخد...
Oil Analysis
جهاز اختبار قوة العزل للزيت JKJQ‑1
JKJQ‑1 هو جهاز اختبار قوة عزل أوتوماتيكي بالكامل مصمم لت...
Oil Analysis
جهاز اختبار قوة العزل للزيت JKJQ‑1A
JKJQ‑1A هو جهاز اختبار محمول أوتوماتيكي بالكامل بكوب واح...
Oil Analysis
جهاز اختبار قوة العزل JKJQ‑1B
JKJQ‑1B هو جهاز اختبار قوة عزل أوتوماتيكي بالكامل بكوب وا...
Contact Angle & Surface Tension
MBP – جهاز قياس ضغط الفقاعة
جهاز MBP 200 من DataPhysics Instruments يستخدم طريقة ضغط الفقاعة الق...
Oil Analysis
ميني فيسك 3000
MiniVisc 3000 هو مقياس لزوجة حركية محمول ثوري يوفر قياسات لزو...
Oil Analysis
مطياف الزيت OIL8000
OIL8000 هو مطياف انبعاث ذري صغير الحجم بقطب قرصي دوار، مثا...
Oil Analysis
مطياف الزيت OIL8000H
OIL8000H هو مطياف انبعاث بصري عالي الأداء بقطب قرصي دوار (RDE...
Oil Analysis
مطياف الزيت PO100
PO100 هو مطياف انبعاث بصري بقطب قرصي دوار (RDE) مصمم خصيصًا ...
Oil Analysis
مطياف الزيت PO300
PO300 هو مطياف انبعاث بصري متقدم بقطب قرصي دوار (RDE) مصمم ل...
Oil Analysis
باي رابتور المحمول
محلل حجم وشكل الجسيمات المحمول Raptor هو أول نظام محمول حق...
Oil Analysis
باي سنتينل برو
SentinelPro هو محلل صور ديناميكي عالي الأداء مصمم للتطبيقات ...
Oil Analysis
عداد جسيمات الزيت المحمول SLPC300
جهاز SLPC300 هو عداد جسيمات زيت محمول يستخدم مبدأ حجب الضو...
Oil Analysis
جهاز أخذ عينات الضغط الموجب والسالب PC‑VES
جهاز أخذ عينات الزيت المحمول PC‑VES مصمم للسوائل عالية ا...
Oil Analysis
روتر أويل R4 (مغير عينات أوتوماتيكي)
R4 RotrOil هو نسخة متقدمة أوتوماتيكية بالكامل من مطياف العن...
Oil Analysis
روتر أويل
جهاز RotrOil هو أحدث جيل من مطيافات الانبعاث البصري بقطب د...
Oil Analysis
عداد جسيمات الزيت المكتبي SLPC100
جهاز SLPC100 هو عداد جسيمات زيت مكتبي يستخدم طريقة العد ال...
Sample Preparation
نظام SNRG B
أنظمة SNRG Block™ للهضم هي أجهزة مختبرية متقدمة مصممة لهضم ...
Oil Analysis
سلسلة سبكترو أويل 100
سلسلة SpectrOil 100 هي محلل عناصر عالي الدقة يعتمد على تقنية ...
Oil Analysis
فيروغرافيا مخبرية T2FM 500
RF500 هو جهاز فيروغرافي دوّار مزدوج الرأس مصمم للتحليل ال...
Oil Analysis
اللزوجة المحمولة السريعة الحركة VS600
مقياس اللزوجة الحركية المحمول VS600 هو جهاز ميداني عالي ا...
مستعد للعثور على الحل المناسب؟
يمكن لفريقنا مساعدتك في اختيار المنتجات المثالية لتطبيقات Engine Testing التطبيقات